{"id":36426,"date":"2026-02-04T13:18:04","date_gmt":"2026-02-04T21:18:04","guid":{"rendered":"https:\/\/www.uwb.edu\/stem\/?page_id=36426"},"modified":"2026-06-30T19:07:54","modified_gmt":"2026-07-01T02:07:54","slug":"instruments","status":"publish","type":"page","link":"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments","title":{"rendered":"Instruments"},"content":{"rendered":"\n<p>Use these links to navigate to product details for each of the instruments:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"#nmr\">NMR (Nuclear Magnetic Resonance) &#8211; DISC-469A<\/a><\/li>\n\n\n\n<li id=\"hplc-tof\"><a href=\"#hplc-tof\">HPLC-TOF (High-Performance Liquid Chromatography-Time-of-Flight) &#8211; DISC-463A<\/a><\/li>\n\n\n\n<li id=\"gc-ms\"><a href=\"#gc-ms\">GC\/MS (Gas Chromatography-Mass Spectrometry) &#8211; DISC-463A<\/a><\/li>\n\n\n\n<li><a href=\"#sem-eds\">SEM-EDS (Scanning Electron Microscope-Energy-Dispersive X-ray Spectroscopy) &#8211; DISC-367A<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"nmr\">NMR (Nuclear Magnetic Resonance)&nbsp;<\/h2>\n\n\n\n<p><strong>Location:<\/strong> Discovery 469A \u2013 NMR (Nuclear Magnetic Resonance)<\/p>\n\n\n\n<p>足彩app哪个是正规的 Bruker Avance III HD 400 MHz NMR spectrometer uses a 5 mm multinuclear broadband observe (BBO) probe and a 24-sample autosampler. This system is designed for routine 1D and 2D NMR experiments, allowing for the detection of multiple nuclear species. 足彩app哪个是正规的 system is capable of automated variable high temperature studies (0\u00b0C to 50\u00b0C) which is well suited for chemical kinetics and relaxation dynamics studies.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"427\" height=\"570\" src=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image.png\" alt=\"A white and blue spectrometer with a probe and an autosampler in a lab\" class=\"wp-image-36428\" srcset=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image.png 427w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image-225x300.png 225w\" sizes=\"auto, (max-width: 427px) 100vw, 427px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Product details<\/th><th>Instrument specifics&nbsp;<\/th><\/tr><\/thead><tbody><tr><td><strong>Manufacturer<\/strong>&nbsp;<\/td><td>Bruker&nbsp;<\/td><\/tr><tr><td><strong>Model<\/strong>&nbsp;<\/td><td>Avance III HD&nbsp;NanoBay&nbsp;<\/td><\/tr><tr><td><strong>Data System<\/strong>&nbsp;<\/td><td>Windows&nbsp;10&nbsp;<\/td><\/tr><tr><td><strong>Installation Date<\/strong>&nbsp;<\/td><td>May 2015&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"hplc-tof\">HPLC-TOF (High-Performance Liquid Chromatography-Time-of-Flight)<\/h2>\n\n\n\n<p><strong>Location:<\/strong> Discovery 463A \u2013 Chemistry Instrumentation room<\/p>\n\n\n\n<p>This Agilent 1290 High Performance Liquid Chromatography (HPLC) with an inline Diode Array Detection (DAD) and 6230 Time of Flight (TOF) mass spectrometer system is used for the identification and quantitation of a wide range of non-volatile compounds. Samples are separated on the Liquid Chromatography (LC) column, passed through the DAD and into the TOF for further detection. 足彩app哪个是正规的 LC has a 120-position autosampler and a DAD with a signal range of 190-640 nm, a \u00b11 nm accuracy and a data rate of up to 160 Hz. 足彩app哪个是正规的 TOF has an Electrospray Ionization (ESI) ion source, a mass range of 25-20,000 m\/z, Mass Spectrometry (MS) acquisition rate of 30 spectra\/sec, a MS mass accuracy (positive) of &lt;1 ppm root mean square (RMS) and a polarity switching duty cycle of &lt; 1 sec.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-constrained wp-block-column-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Agilent 1290 High Performance Liquid Chromatography (HPLC)<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"361\" height=\"543\" src=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/3eb58cda-5e90-406f-8137-11cb950a4ddc-1.jpg\" alt=\"Liquid chromatography system with purging bottles and additional lab equipment attached\" class=\"wp-image-36435\" srcset=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/3eb58cda-5e90-406f-8137-11cb950a4ddc-1.jpg 361w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/3eb58cda-5e90-406f-8137-11cb950a4ddc-1-199x300.jpg 199w\" sizes=\"auto, (max-width: 361px) 100vw, 361px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-constrained wp-block-column-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">6230 Time of Flight (TOF) mass spectrometer system<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"327\" height=\"540\" src=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/beb8dbbd-ec3e-4abe-9aee-c813ab61df12-2.jpg\" alt=\"Mass spectrometer system with bottles attached\" class=\"wp-image-36436\" style=\"aspect-ratio:0.605559849676164;width:328px;height:auto\" srcset=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/beb8dbbd-ec3e-4abe-9aee-c813ab61df12-2.jpg 327w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/beb8dbbd-ec3e-4abe-9aee-c813ab61df12-2-182x300.jpg 182w\" sizes=\"auto, (max-width: 327px) 100vw, 327px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"533\" src=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/undefined.jpg\" alt=\"HPLC-TOF in the Discovery 463A - Chemistry Instrumentation room, with various equipment throughout the room\" class=\"wp-image-36429\" style=\"aspect-ratio:1.5009636322679147;width:962px;height:auto\" srcset=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/undefined.jpg 800w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/undefined-300x200.jpg 300w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/undefined-768x512.jpg 768w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/undefined-600x400.jpg 600w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">HPLC-TOF located next to one another in the Discovery 463A \u2013 Chemistry Instrumentation room.<\/figcaption><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"936\" height=\"624\" src=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/undefined.png\" alt=\"Full view of the Discovery 463A \u2013 Chemistry Instrumentation room with the HPLC-TOF located directly on the left, with various equipment throughout the room\" class=\"wp-image-36430\" style=\"aspect-ratio:1.500012181751736;width:957px;height:auto\" srcset=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/undefined.png 936w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/undefined-300x200.png 300w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/undefined-768x512.png 768w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/undefined-600x400.png 600w\" sizes=\"auto, (max-width: 936px) 100vw, 936px\" \/><figcaption class=\"wp-element-caption\">Full view of the Discovery 463A \u2013 Chemistry Instrumentation room with the HPLC-TOF located directly on the left.<\/figcaption><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Product details<\/th><th>Instrument specifics<\/th><\/tr><\/thead><tbody><tr><td>Manufacturer<\/td><td>Agilent Technologies<\/td><\/tr><tr><td>Model<\/td><td>1290-6230 with DAD<\/td><\/tr><tr><td>Data System<\/td><td>Windows 10, Agilent MassHunter Workstation Acquisition 11.0, Agilent MassHunter Workstation Qualititative Analysis 10.0, Agilent MassHunter Workstation BioConfirm 11.0<\/td><\/tr><tr><td>Installation Date<\/td><td>March 2023<\/td><\/tr><tr><td>Column(s)<\/td><td>Agilent ZORBAX Eclipse: XDB-C8 (P\/N 993967-906), XDB-C18 (P\/N 993967-902), SB-C8 (P\/N 871700-906, 861953-906 &amp; 863953-906) and Plus C18 (P\/N 959757-902 &amp; 959993-902)<br>Agilent ZORBAX: Extend-C18 (P\/N 727700-902)<br>Agilent AdvanceBio: SEC 200A (P\/N PL1980-3201PK)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"gc-ms\">GC\/MS (Gas Chromatography-Mass Spectrometry)<\/h2>\n\n\n\n<p><strong>Location:<\/strong> Discovery 463A \u2013 Chemistry Instrumentation room<\/p>\n\n\n\n<p>This Agilent 7890B Gas Chromatography (GC) and 5977A Mass Selective Detector (MSD) system is used for the identification and quantitation of volatile or semi-volatile organic molecules. Samples are introduced manually or with the help of the 150-positon automatic liquid sampler. 足彩app哪个是正规的 GC then separates analytes by column chromatography before they are transferred to the MSD where they are further filtered and detected. GC\/MS instrument processing is commonly used in environmental sciences, food safety and petrochemical industries.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-constrained wp-block-column-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">Agilent 7890B Gas Chromatography (GC)<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"444\" height=\"295\" src=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/SEM-Machines.png\" alt=\"Gas Chromatography system on a counter in a lab equipment room\" class=\"wp-image-36446\" srcset=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/SEM-Machines.png 444w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/SEM-Machines-300x199.png 300w\" sizes=\"auto, (max-width: 444px) 100vw, 444px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-constrained wp-block-column-is-layout-constrained\">\n<h3 class=\"wp-block-heading\">5977A Mass Selective Detector (MSD)<\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"444\" height=\"295\" src=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/undefined-1.png\" alt=\"Close up of a Mass Selective Detector system with a screen and 6 buttons. Screen reads &quot;Foreline Pressure 81.697 mTorr Ready&quot;\" class=\"wp-image-36445\" srcset=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/undefined-1.png 444w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/undefined-1-300x199.png 300w\" sizes=\"auto, (max-width: 444px) 100vw, 444px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"936\" height=\"624\" src=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image-1.png\" alt=\"Full view of the Discovery 463A \u2013 Chemistry Instrumentation room with the MSD on the left and GC on the right-hand table, with various equipment throughout the room\" class=\"wp-image-36437\" style=\"aspect-ratio:1.500012181751736;width:962px;height:auto\" srcset=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image-1.png 936w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image-1-300x200.png 300w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image-1-768x512.png 768w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image-1-600x400.png 600w\" sizes=\"auto, (max-width: 936px) 100vw, 936px\" \/><figcaption class=\"wp-element-caption\">Full view of the Discovery 463A \u2013 Chemistry Instrumentation room with the MSD on the left and GC on the right-hand table.<\/figcaption><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Product details<\/th><th>Instrument specifics<\/th><\/tr><\/thead><tbody><tr><td>Manufacturer<\/td><td>Agilent Technologies<\/td><\/tr><tr><td>Model<\/td><td>7890B-5977A<\/td><\/tr><tr><td>Data System<\/td><td>Windows 10, Agilent MassHunter GCMS Data Acquisition 10, Agilent MassHunter Workstation Qualitative Analysis 10.0, Agilent MSD Chemstation Classic Data Analysis (G1701FA)<\/td><\/tr><tr><td>Installation Date<\/td><td>August 2014<\/td><\/tr><tr><td>Column(s)<\/td><td>DE07150116<br>Agilent J&amp;W: DB-5MS (P\/N 122-5532E), HP5-MS (P\/N 19091S-433E) and HP-PLOT\/Q (P\/N 19095P-QO4E)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sem-eds\">SEM-EDS (Scanning Electron Microscope-Energy Dispersive X-ray Spectroscopy)<\/h2>\n\n\n\n<p><strong>Location:<\/strong> Discovery 367A \u2013 SEM-EDS<\/p>\n\n\n\n<p>State-of-the-art Field Emission <a href=\"https:\/\/www.uwb.edu\/stem\/graduate\/ms-electrical-computer-engineering\/research\/laboratories\/scanning-electron-microscope\">Scanning Electron Microscope<\/a> capable of achieving resolutions up to 1 nm. EM Wizard software assists with image optimization and capture. 足彩app哪个是正规的 SU5000 features Variable Pressure (VP) capability to handle non-conductive samples charging without Au coating. 足彩app哪个是正规的 system is equipped with both secondary electron detectors and backscatter electron detectors. Energy-Dispersive X-ray Spectroscopy (EDS) capability is also provided for elemental analysis of samples.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"936\" height=\"624\" src=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image-2.png\" alt=\"A room with a Field Emission Scanning Electron Microscope on the left, and a table with two monitors, a keyboard, mouse, chair and various equipment on the right. 足彩app哪个是正规的 monitors show microscope data.\" class=\"wp-image-36438\" srcset=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image-2.png 936w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image-2-300x200.png 300w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image-2-768x512.png 768w, https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image-2-600x400.png 600w\" sizes=\"auto, (max-width: 936px) 100vw, 936px\" \/><figcaption class=\"wp-element-caption\">View of the Discovery 367A &#8211; Chemistry Instrumentation room with the SEM-EDS.<\/figcaption><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Product details<\/th><th>Instrument specifics<\/th><\/tr><\/thead><tbody><tr><td>Manufacturer<\/td><td>Hitachi High-Tech<\/td><\/tr><tr><td>Model<\/td><td>SU5000<\/td><\/tr><tr><td>Data System<\/td><td>Windows 7<\/td><\/tr><tr><td>Installation Date<\/td><td>February 2018<\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Use these links to navigate to product details for each of the instruments: NMR (Nuclear Magnetic Resonance)&nbsp; Location: Discovery 469A \u2013 NMR (Nuclear Magnetic Resonance) 足彩app哪个是正规的 Bruker Avance III HD 400 MHz NMR spectrometer uses a 5 mm multinuclear broadband observe (BBO) probe and a 24-sample autosampler. This system is designed for routine 1D and&#8230;<\/p>\n","protected":false},"author":637,"featured_media":0,"parent":36422,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_is_archived":false,"_archived_contact_email":"","footnotes":""},"class_list":["post-36426","page","type-page","status-publish","hentry"],"acf":{"related_links":{"toggle_visibility":false,"link_1":"","link_2":"","link_3":"","link_4":"","link_5":""},"highlight_box":{"toggle_visibility":false,"title":"","content":"","button":"","button_style":"angled-purple-button","button_screen_reader_text":""},"contact_type_1":{"toggle_visibility":true,"contact_title":"Christy Cherrier","email":"ccherr@uw.edu","phone":"","box":"","address_line_1":"","address_line_2":"","location":""},"contact_type_2":{"toggle_visibility":false,"contact_title":"","email":"","phone":"","box":"","address_line_1":"","address_line_2":"","location":""},"social_media":{"toggle_visibility":false,"facebook_url":"","instagram_url":"","linkedin_url":"","twitter_url":"","youtube_url":""},"blog_archive_sidebar_visibility":false},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Instruments - School of Science, Technology, Engineering &amp; Mathematics<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Instruments - School of Science, Technology, Engineering &amp; Mathematics\" \/>\n<meta property=\"og:description\" content=\"Use these links to navigate to product details for each of the instruments: NMR (Nuclear Magnetic Resonance)&nbsp; Location: Discovery 469A \u2013 NMR (Nuclear Magnetic Resonance) 足彩app哪个是正规的 Bruker Avance III HD 400 MHz NMR spectrometer uses a 5 mm multinuclear broadband observe (BBO) probe and a 24-sample autosampler. This system is designed for routine 1D and...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments\" \/>\n<meta property=\"og:site_name\" content=\"School of Science, Technology, Engineering &amp; Mathematics\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-01T02:07:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image.png\" \/>\n\t<meta property=\"og:image:width\" content=\"427\" \/>\n\t<meta property=\"og:image:height\" content=\"570\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments\",\"url\":\"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments\",\"name\":\"Instruments - School of Science, Technology, Engineering &amp; Mathematics\",\"isPartOf\":{\"@id\":\"\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments#primaryimage\"},\"image\":{\"@id\":\"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments#primaryimage\"},\"thumbnailUrl\":\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image.png\",\"datePublished\":\"2026-02-04T21:18:04+00:00\",\"dateModified\":\"2026-07-01T02:07:54+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments#primaryimage\",\"url\":\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image.png\",\"contentUrl\":\"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image.png\",\"width\":427,\"height\":570},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.uwb.edu\/stem\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Industry partners\",\"item\":\"https:\/\/www.uwb.edu\/stem\/industry-partners\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"STEM Instrumentation Facility\",\"item\":\"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Instruments\"}]},{\"@type\":\"WebSite\",\"@id\":\"\/#website\",\"url\":\"\/\",\"name\":\"School of Science, Technology, Engineering &amp; Mathematics\",\"description\":\"Just another UW Bothell site\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Instruments - School of Science, Technology, Engineering &amp; Mathematics","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments","og_locale":"en_US","og_type":"article","og_title":"Instruments - School of Science, Technology, Engineering &amp; Mathematics","og_description":"Use these links to navigate to product details for each of the instruments: NMR (Nuclear Magnetic Resonance)&nbsp; Location: Discovery 469A \u2013 NMR (Nuclear Magnetic Resonance) 足彩app哪个是正规的 Bruker Avance III HD 400 MHz NMR spectrometer uses a 5 mm multinuclear broadband observe (BBO) probe and a 24-sample autosampler. This system is designed for routine 1D and...","og_url":"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments","og_site_name":"School of Science, Technology, Engineering &amp; Mathematics","article_modified_time":"2026-07-01T02:07:54+00:00","og_image":[{"width":427,"height":570,"url":"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments","url":"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments","name":"Instruments - School of Science, Technology, Engineering &amp; Mathematics","isPartOf":{"@id":"\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments#primaryimage"},"image":{"@id":"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments#primaryimage"},"thumbnailUrl":"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image.png","datePublished":"2026-02-04T21:18:04+00:00","dateModified":"2026-07-01T02:07:54+00:00","breadcrumb":{"@id":"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments#primaryimage","url":"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image.png","contentUrl":"https:\/\/www.uwb.edu\/stem\/wp-content\/uploads\/sites\/31\/2026\/02\/image.png","width":427,"height":570},{"@type":"BreadcrumbList","@id":"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility\/instruments#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.uwb.edu\/stem\/"},{"@type":"ListItem","position":2,"name":"Industry partners","item":"https:\/\/www.uwb.edu\/stem\/industry-partners"},{"@type":"ListItem","position":3,"name":"STEM Instrumentation Facility","item":"https:\/\/www.uwb.edu\/stem\/industry-partners\/instrumentation-facility"},{"@type":"ListItem","position":4,"name":"Instruments"}]},{"@type":"WebSite","@id":"\/#website","url":"\/","name":"School of Science, Technology, Engineering &amp; Mathematics","description":"Just another UW Bothell site","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.uwb.edu\/stem\/wp-json\/wp\/v2\/pages\/36426","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.uwb.edu\/stem\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.uwb.edu\/stem\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.uwb.edu\/stem\/wp-json\/wp\/v2\/users\/637"}],"replies":[{"embeddable":true,"href":"https:\/\/www.uwb.edu\/stem\/wp-json\/wp\/v2\/comments?post=36426"}],"version-history":[{"count":17,"href":"https:\/\/www.uwb.edu\/stem\/wp-json\/wp\/v2\/pages\/36426\/revisions"}],"predecessor-version":[{"id":36705,"href":"https:\/\/www.uwb.edu\/stem\/wp-json\/wp\/v2\/pages\/36426\/revisions\/36705"}],"up":[{"embeddable":true,"href":"https:\/\/www.uwb.edu\/stem\/wp-json\/wp\/v2\/pages\/36422"}],"wp:attachment":[{"href":"https:\/\/www.uwb.edu\/stem\/wp-json\/wp\/v2\/media?parent=36426"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}